• Phone

    86-10-88121032

  • Address

    Room C121, Fengyu Office Building, No. 115 Fucheng Road, Haidian District, Beijing, China

  • E-mail

    k@waimaotong.com

LatestProducts

                            BROTIE Trace Oxygen Analyzer

BROTIE Trace Oxygen Analyzer

BROTIE Trace Oxygen Analyzer,BROTIE,Machinery & Industrial Parts,Measurement & Analysis Instruments,Analyzers,Gas Analyzers
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
BROTIE
Measure Range:
0-10ppm, 0-100ppm, 0-1000ppm, 0-1% O2
Accuracy:
≤±2% in FS range
Response Time:
90% of final FS reading ≤10 seconds
Display Resolution:
0.01ppm
Repeatability:
≤±1%
Ambient Temp.:
0℃~+45℃
Power Supply:
220±10% VAC, 50/60Hz, power loss≤10VA
Contact Capacity:
125VAC 0.3A, 110VDC 0.3A, 30VDC 1A
Sensor Life:
24 months at 25℃ and 1 atm
Warranty:
12 months analyzer; 12 months sensor
Packaging & Delivery
Packaging Details
carton
Delivery Time
3 Days

BROTIE Trace Oxygen Analyzer

BROTIE Trace Oxygen Analyzer

Features                                                                                                   

*  imported fuel cell oxygen sensor, long life, high precision and fast response

*  Measuring oxygen concentration in H2 or deoxidize gas

*  Inner special gas-route protects the sensor when it exposures into the air for long time during out of the power or cutting off the gas-route automatically.

*  Setting Upper and lower alarm values freely during the measure ranges.

*  4-20mA signal output

*  One standard RS232C or RS485 interface 

 

Technical Specifications                                                                                     

Measure Range:                       0-10ppm, 0-100ppm, 0-1000ppm, 0-1% O2

Accuracy:                                    ≤±2% in FS range

Response Time:                      90% of final FS reading ≤10 seconds

Display Resolution:                 0.01ppm

Stability:                                     Zero drift ≤±2% of FS/7d

                                                    Span drift ≤±2% of FS/7d

Repeatability:                            ≤±1%

Ambient Temp.:                       0~+45

Sampling Gas Flow:                 200~400ml/mim

Sampling Gas Pressure:           0.05MPa≤Inlet pressure≤0.5Mpa

Power Supply:                           220±10% VAC, 50/60Hz, power loss≤10VA

Measure Medium:                     H2, He, hydrocarbons, inert & acidic gases

Contact Capacity:                     125VAC 0.3A, 110VDC 0.3A, 30VDC 1A

Sensor Life:                              24 months at 25℃and 1 atm

Warranty:                                  12 months analyzer; 12 months sensor

Weight:                                     3kg 

Installation Dimension:             133mm×133mm×250mm (W×H×D)