                            Process Trace Oxygen Analyzer

Process Trace Oxygen Analyzer

Process Trace Oxygen Analyzer,brotie,Machinery & Industrial Parts,Measurement & Analysis Instruments,Analyzers,Gas Analyzers
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
brotie
Model Number:
CI-IN90
Sensor Type:
Electro-chemical Type
Measure Mode:
Continuous Process Type
Installation:
Panel Mounted
Electrical Structure:
Non hazardous ground
Sensitivity:
0.5% F.S
Response Time:
0-10ppm T90<60s under 25℃
Down Time:
Air purity(20.94%)to trace oxygen purity should be about 2 hours.
Power Supply:
AC85-265V,47~63Hz
Power Consumption:
Lower than 20VA
Communication Mode:
2 Direction RS232 Communication
Packaging & Delivery
Packaging Details
carton
Delivery Time
3 Days

Process Trace Oxygen Analyzer

1. 240×128 LCD display oxygen purity and other set data;
2. Special inner installed protection gas way, when suddenly power off, it will automatically shut down the gas way to protect the sensor from being exposed in the air;
3. New structure measure room to meet the requirement of replacing sensor quickly;
4. 0-25% manually set measure range, the minimum measure range is 0-10ppm,the maximum measure range is 0-10000ppm;
5. 2 way SPST alarm function;
6. RS232 directional communication port to connect with the computer or other data communication equipment;
7. Isolated 4-20mA DC standard signal output,0-100mV,0-1V or 0-10V analogue output can be choose from, but need to specified when place the order; (please note signal output only 1 kind, please choose one kind based on your applications)
 
 
Technique Specifications

1. Type:CI-IN90 Trace Oxygen Analyzer
2.      Sensor Type:Electro-chemical Type
3.      Measure Mode:Continuous Process Type
4.      Installation:Panel Mounted
5.      Electrical Structure:Non hazardous ground
6.      Measure Range:0-25% manually set range, minimum measure range is 0-10ppm,Maximum measure range is 0-10000ppm
7.      Sensitivity:0.5% F.S
8.      Accuracy:0-1000ppm       ±2%F.S
          0-100ppm        ±3%F.S
          0-10ppm         ±5%F.S
9.      Stability: 0-1000ppm    ±1%F.S
         0-100ppm     ±1.5%F.S
         0-10ppm      ±2.5%F.S
10.  Response Time:0-10ppm  T90<60s under 25
11.  Down Time:Air purity(20.94%)to trace oxygen purity should be about 2 hours.
12.  Temperature Automatically Compensation:thermometer embedded in the sensor room, feedback the temperature information to the micro-processor and compensate the temperature;
13.  Power Supply:AC85-265V,47~63Hz
14.  Power Consumption:Lower than 20VA
15.  Signal Output:4-20mA DC Isolated standard signal output;0-100mV,0-1V or
0-10V DC analogue output should be specified when place the order.
16.  Alarm Contact Point:2 way alarm, all SPST
17.  Contact Capacity:3A when AC 240V
18.  Display Resolution:1-25%           0.01%
                  100-10000ppm    1 ppm
                 10-100 ppm      0.1 ppm
                 0-10 ppm        0.01 ppm
19.  Communication Mode:2 Direction RS232 Communication
20.  Environment Temperature:0-45
21.  Environment Humidity:lower than 80%RH
22.  Sample Gas Temperature:0-45
23.  Sample Gas Pressure:35~210KPa
24.  Sample Gas Flow:1.2L/min
25.  Flow Meter Range:0-2L/min
26.  Flow Control Valve:Inner Needle Valve
27.  Gas Inlet:1/4 inch Swagelok type,stainless steel material
28.  Gas Outlet:1/4 inch Swagelok type,stainless steel material
29.  Sensor Room:Aluminum nickel plated,Cover tighten type sealed
30.  Gas Way:1/8 inch 316 stainless steel
31.  Background Gas:CI-IN90H for N2, H2, He, Ar, and HC
CI-IN90C when sample gas contain CO2 purity that higher than 1000ppm
32.  Sensor Life:1 atm pressure, 25℃,2 years life
33.  Sensor Warranty:14 months
34.  Analyzer Warranty:18 months
35.  Calibration:every 3 months is recommended, 3 kinds of gas is recommended: 3ppm, 800ppm, 300~500ppm (used for testing after the calibration).
36.    Sensor Protection:2 solenoid pilot actuated valve installed respectively at the sensor rooms inlet and outlet, by the solenoid pilot actuated valve to control whether the valve will flow the sensor or not, when exposed in the high purity oxygen environment, the user can shut down the gas way through the solenoid pilot actuated valve to protect the sensor;
37.  Self-check function:notice during the communication, for example power supply self-check, previous level self-check, analogue output self-check, etc.
38.  Front Panel Size:275mm(W)*190mm(H)
39.  Analyzer Size:222(W)*178.5(H)*300mm (D)
40.  Panel Install Hole Cut Dimension:224(W)*185mm(H)
41.  Analyzer Weight:6.8KG
 
Specially Notice
l   The gas inlet pressure should be 35-210KPa before inputting the sample gas into the analyzer,the sample gas flow should be controlled at 1-1.5L/min by the needle valve, the flow should not over 2 L/min,please operate as this notice, or it will damage the sensor, flow meter and pressure sensor;
l   The gas outlet should not be blocked, or the safety valve will open automatically, but still if blocked the gas outlet, it maybe damage the sensor;
l   Based on the performance of the sensor, work in lower than 1% purity environment is recommended to extend the sensor life;
l   To lower the PPm level oxygen purity, the sample gas way, the stainless steel inner polished pipe is recommended, and the sealing state should be very good.