• Phone

    86-10-88121032

  • Address

    Room C121, Fengyu Office Building, No. 115 Fucheng Road, Haidian District, Beijing, China

  • E-mail

    k@waimaotong.com

LatestProducts

                            BROTIE CO2 analyzer

BROTIE CO2 analyzer

BROTIE CO2 analyzer,BROTIE,Machinery & Industrial Parts,Machinery,Energy & Mineral Equipment,Gas Generation Equipment
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Beijing, China (Mainland)
Brand Name:
BROTIE
Model Number:
2000
Usage:
carbon dioxide
Production Rate:
0-100%
Range:
0.01%-5%/10%/50%/100%
Accuracy:
≤±2% in full FS range
Response Time:
90% of final FS reading≤ 30 seconds
Stability:
Range drift ≤±2% of FS/7d
Repeatability:
≤±0.5%
Warm-up:
≤7 minutes
Fluctuated Output:
0.5% F.S
Ambient Temp:
-10℃-+60℃
Ambient Humidity:
≤80%RH
Sample Gas Flow::
400ml±10ml/mim
Packaging & Delivery
Packaging Details
carton packaging
Delivery Time
10days after receiving payment

Specifications

Measuring H2 for ammonia&fertilize production
Measuring CO2 in combustion exhaust gas
Measuring Ar in ammonia distillation

Thermal Conductivity Gas Analyzer 

Determining gas concentrations by measuring the thermal conductivity of the gas, CI2000-RQD analyzer uses advanced thermal conductivity sensor with single chip technology. It adopts platinum thread as sense organ to make up Imbalance Bridge, which output signal has a relationship with tested gas volume. And the single chip will magnify, sieve wavelength, modify linearly and criteria the signal by electric procedure. And then it will output direct ratio signal to the tested gas concentration.

 

Features                                                                                                       

*  imported corrosion-resistance sensor, intercross resistance and advanced digital processing

*  Low drift electric bridge with high stability and good reliability

*  Concise menu, simple operation

*  Setting upper and lower alarm values arbitrarily during the measurement range

*  Connected to a computer via the standard RS232 or RS485 interface.  

 

Technical Specifications                                                                                       

Range:                                        0.01%-5%/10%/50%/100%

Accuracy:                                       ≤±2% in full FS range

Stability:                                       Zero drift ≤±2% of FS/7d

                                                      Range drift ≤±2% of FS/7d

Repeatability:                               ≤±0.5%

Warm-up:                                     ≤7 minutes

Response Time:                          90% of final FS reading≤ 30 seconds

Fluctuated Output:                       0.5% F.S.

Ambient Temp.:                          -10°C~+60°C

Ambient Humidity:                      ≤80%RH

Sample Gas Flow:                     400ml±10ml/mim

Sample Gas Pressure:              0.05MPa≤Inlet pressure≤0.45Mpa

Power Supply:                             220±10% VAC, 50/60Hz, power loss≤15VA

Warranty:                                     12 months analyzer; 12 months sensor

Weight:                                        4kg

Installation Dimension:             482.5mm×177mm×300mm (W×H×D)

  

Applications                                                                                                     

 Measuring H2 concentration in supply gas and cycle gas for ammonia production

 Measuring H2 concentration in fertilize production

Measuring exceed H2 concentration in argon production

Measuring H2 concentration in cycle gas for hydrogen-cooled generator

Measuring H2 concentration in environment air or industrial container

Measuring CO2 concentration in combustion exhaust gas of industrial boilers or furnaces

Measuring Ar concentration in ammonia distillation

Measuring Ar concentration in percent argon

 

BROTIE CO2 analyzer